ENTERPRISE SERIES

1000-10,000 VA

SALIENT FEATURES:

 

  • Compact Enterprise UPS protects hardware and data in networks and computer systems from voltage fluctuations and power problems: power failure, frequency variations, voltage amplitude variations, spikes, noise and other transients, sags and brownouts, voltage surges, and more.
  • When power problems occur, the batteries deliver the necessary power to the inverter. In overload or short-circuit conditions, the UPS automatically switches mains power directly through to the load to guarantee an un-presented level of power supply security.
  • At times of no power failure, Enterprise Series UPS converts the mains AC voltage into DC voltage, which supplies batteries and an inverter with energy, so as to insure the data over the entire network. Therefore, the power used by the load is the purified sine wave via regulated voltage and regulated frequency with noisy signals filtered..
  • True on-line double conversion design. When the UPS is powered on, it immediately performs an inspection of the components such as the inverter the battery as well as the load, so as to detect any problem in time to avoid causing any negligence or loss. .
  • RS-232 communication interface enables direct on-screen monitoring of the status of power supply and UPS, so as to simplify the network management work and improve the reliability of computer system. .
  • Mercury series UPS systems are equipped with a SNMP slot to allow remote communication among various operation systems and remote monitoring of the UPS. .
  • Real-time alarm silencing function eliminates the unnecessary and annoying noises. .
  • Output short circuit protection.
  • Input over voltage and input frequency variation protection..
  • Auto restart and cold restart function.
  • Power factor correction improves the power efficiency

Enterprise Series

E1000 /E 1000-X

E2000 /E 2000-X

E3000 /E 3000-X

OPERATION 

Online double-conversion system

OUTPUT POWER 

1000VA

2000VA

3000VA

INPUT

 

 

 

Input method

                   Single-phase

Nominal Voltage

160-275V at 70% to 100% load,
150-285V at 50% to 70 % load
130-290V at      0 to 50% load

Frequency

                 50 /60 Hz ± 5% automatic frequency recognition

Input Power factor
Correction

                0.95

OUTPUT

 

Type

Single-phase

Voltage

1 N AC 208, 220, 230, 240 +/- 3% (adjustable)

Frequency

automatic frequency check  50Hz +/- 5%  (Line Model)
                                       50Hz +/-0. 5%  (Battery Model)

Wave Form

Sine

Distortion Factor

maximum 4% (linear load)
Maximum 7 %( non-Linear load)

Resistance to short circuits/ overload

130% of the rated load for 2 sec, 110% for 10 sec.,
output short-circuit proof

Distortion Co-efficient

 < 3% (linear load) / 4%(non-linear load)

Crest Factor

               03:01:00

Automatic Bypass

Integral

AC- AC

   Zero

Inverter to Bypass

2.5 cms (typical)

BATTERY

 

Output on battery

Sealed lead-acid battery, integrated, maintenance-free

Size

7Ah/12V

7Ah/12V

7Ah/12V

Number

3

8

8

BackUp Time
(Full Load)

7 min

10 min

6 min

Recharge Time

6 hrs to 90%

6 hrs to 90%

6 hrs to 90%

Charging Current

1 to 13 amps

1 to 13 amps

1 to 13 amps

Charging Voltage

41.1V+/- 0.6V

110V+/- 0.5V

110V+/- 0.5V

Status

OVERLOAD, LOAD, BYPASS, INVERTER, BATTERY , LINE ALARM
Load and Battery are shown separately)

Efficiency

       > 90%

Output

  0.7pf

PROTECTION

 

Battery Mode

Beeps every 5 seconds

Battery Low

Beeps every 5 seconds

Overload

Beeps twice every second

Fault

Continuous Beeping

MECHANICAL

 

Noise at 1 meter

< 41 dB

 < 50 dB

< 50 dB

Alarm at 1 meter dist

Acoustic signal for battery reserve time, UPS fault

DB 9-pin Port/RS 232 Port

Windows, Novell and Linux Systems acceptable

SNMP (Optional)

Remote Power management available via software and web browser

Operating Temperature

 0 to + 40 degree Centigrade; 32-104 degree Fahrenheit

Relative Humidity

 20 to 90% ( no condensation)

W X H x D (mm)

145 X 225 X 400

200 X 350 X 475

200 X 350 X 475

Net Weight (kg)

16

8.5 / 48

14 / 48

Brochure
(None)